Model
AK6003D

P1

P2

DC Output(0~40¡É)
0~60V / 0~3A
0~60V / 0~3A
Resolution(Programming/Readback)
1mV / 1mA
1mV / 1mA
Resolution(Meter)
1mV / 1mA
1mV / 1mA

Programming Accuracy

± (% of output + offset)

V
±<(0.05%+20mV)
±<(0.10%+25mV)
C
±<(0.10%+5mA)
±<(0.10%+10mA)

Readback Accuracy

± (% of output + offset)

V
±<(0.05%+15mV)
±<(0.10%+20mV)
C
±<(0.10%+3mA)
±<(0.10%+7mA)

Ripple & Noise

(20Hz to 20MHz)

V
±<4mVp-p
±<8mVp-p
C
±<1mArms
±<1mArms

Load Regulation

± (% of output + offset)

V
±<(0.01%+2mV)
±<(0.01%+2mV)
C
±<(0.01%+1mA)
±<(0.01%+1mA)

Line Regulation

± (% of output + offset)

V
±<(0.01%+2mV)
±<(0.01%+2mV)
C
±<(0.01%+1mA)
±<(0.01%+1mA)

Voltage Programming Speed

Full Load(u:up, d:down)

u
16msec
16msec
d
20msec
20msec


   Transient Response Time - Less than 50us for output recover to within 15mV following a                                               change in current output from full load to half load

 

   ¡Ø The above specification is measured from its front output terminals after 1 hour warm-up        and recalibration at 25¡É, ±(% of operating output+offset).

   ¡Ø In case of using rear output terminals or remote sensing facilities, new calibration is         required. Please study the calibration procedure in the ¡°User¡¯s Guide¡± before performing         new calibration.

   ¡Ø Standard Input Voltage : 220Vac±10%/48~62Hz, Optional inputs are available.

 

    >> IMAGES    >> Specifications                                                                              Click for more specifications !!  

      * Single Display

      * Dual Display

      * Interface

Model

AK1205D

AK3003D

AK3005D

AK6003D

 

Voltage

12V x 2

30V x 2

30V x 2

60V x 2

 

Current

5A x 2

3A x 2

5A x 2

3A x 2

 

Watt

60W x 2

90W x 2

150W x 2

180W x 2

 

      * Single front output

      * Single rear output

      * Dual front output

      * Dual rear output

      * K Dual Knob & buttern

      * K Dual left side

      * K Dual right side

 

   >> Features

      • Bench-top and 19-inch standard rack mountable

      • Self-compensation by monitoring output and display

      • CV/CC mode automatic crossover by setup limit

      • Storable up to 10 settings at each output port

      • Pattern output operation

      • Power fail feature to recall the latest setting value

      • DUT protection by OVP & OCP

      • Rear output enable

      • Track function which interlocks P2